General specifications | |
---|---|
Detection type | photoelectric sampling |
Pulse count | max. 50000 |
UL File Number | E223176 |
Functional safety related parameters | |
MTTFd | 140 a |
Mission Time (TM) | 20 a |
L10 | 50 E+9 at 1750 rpm |
Diagnostic Coverage (DC) | 0 % |
Electrical specifications | |
Operating voltage | 10 ... 30 VИли отправьте нам запрос наutput circuit" in the ordering information) |
No-load supply current | max. 70 mA |
Output | |
Output type | push-pull, incremental or RS-422, incremental (see "Output circuit" in the ordering information) |
Voltage drop | < 2.5 V (push-pull, incremental) |
Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected (push-pull, incremental) max. per channel 20 mA , short-circuit protected, reverse polarity protected (RS422, incremental) |
Output frequency | max. 200 kHz |
Rise time | 600 ns |
De-energized delay | 600 ns |
Connection | |
Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin |
Cable | ?6.5 mm, 4 x 2 x 0.14 mm2, 1 m |
Standard conformity | |
Degree of protection | DINEN60529, IP65 |
Climatic testing | DINEN60068-2-78 |
Emitted interference | EN61000-6-4:2007/A1:2011 |
Noise immunity | EN61000-6-2:2005 |
Shock resistance | DINEN60068-2-27, 100g, 6ms |
Vibration resistance | DINEN60068-2-6, 10g, 10...2000Hz |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Ambient conditions | |
Operating temperature | -5 ... 70 °C (23 ... 158 °F) , movable cable -20 ... 70 °C (-4 ... 158 °F), fixed cable |
Storage temperature | -40 ... 80 °C (-40 ... 176 °F) |
Mechanical specifications | |
Material | |
Mass | approx. 900 g |
Rotational speed | max. 3500 min -1 |
Starting torque | ? 6 Ncm |
Shaft load |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |